Arterial carbon dioxide as an endogenous "contrast agent" for blood flow imaging


I nearly called this post Low Frequency Oscillations - part III since it closely follows the subject material I covered in the last two posts. But this is a slight tangent. Following the maxim "One scientist's noise is another scientist's signal," in this post I want to look at the utility of systemic LFO to map blood flow dynamics, an idea that was suggested in 2013 by Lv et al. based on the earlier work from Tong & Frederick that I reviewed last post. There is also at least one review of this topic, from 2017.

Let me first recap the last post. There is sufficient evidence, supported by multiple direct and indirect lines of inquiry, to suggest a blood-borne contrast mechanism that produces a prominent fluctuation at around 0.1 Hz in resting-state fMRI data. (Here, I assume a standard T₂*-weighted EPI acquisition for the resting-state fMRI data.) Furthermore, the same fluctuation can be found anywhere in the body. That is, the fluctuation is truly systemic. The best explanation to date is that non-stationary arterial CO₂ concentration, brought about by variations in breathing rate and/or depth, produces changes in arterial tone by virtue of the sensitivity of smooth muscle walls to the CO₂ dissolved in arterial blood. I shall assume such a mechanism throughout this post, while noting that the actual mechanism is less critical here than whether there is some utility to be exploited.

In the title I put "contrast agent" in quotes. That's because the CO₂ isn't the actual contrast agent, but a modulator of contrast changes. When the smooth muscle walls of an artery sense a changing CO₂ concentration, they either expand or contract locally, modulating the blood flow through that vessel. In the brain, a change in a blood vessel's diameter causes a concomitant change cerebral blood volume (CBV), hence cerebral blood flow (CBF). There may be a local change in magnetic susceptibility corresponding to the altered CBV in the arteries and capillaries. But the altered CBF will definitely produce the well-known change in magnetic susceptibility in and around the venous blood that can be detected downstream of the tissue, i.e. the standard BOLD effect. The actual contrast we detect is by virtue of changes in T₂* (for gradient echo EPI), plus the possibility of some flow weighting of the arterial blood depending on the combination of flip angle (FA) and repetition time (TR) being used. As a shorthand, however, I shall refer to arterial CO₂ as the endogenous contrast agent because whenever an artery senses a change in CO₂ concentration, there will be a concomitant change in vessel tone, and we will see a cascade of signal changes arising from it. (See Note 1 for some fun with acronyms!)


Time shift analysis

Most published studies attempting to exploit systemic LFO have used fixed time shifts, or lags, in their analysis. You just need a few minutes' worth of BOLD fMRI data, usually resting state (task-free). The analysis is then conceptually straightforward:
  1. Define a reference, or "seed," time course;
  2. Perform cross correlations between the "seed" and the time course of each voxel, using a set of time shifts that typically spans a range of 15-20 seconds (based on the expected brain hemodynamics);
  3. Determine for each voxel which time shift gives the largest cross correlation value, and plot that value (the delay, in seconds) to produce a lag map.

There are experimental variables, naturally. The duration of the BOLD time series varies, but most studies to date have used the 5-8 min acquisition that's common for resting-state connectivity. Some studies filter the data before starting the analysis. Different studies also tend to choose different seeds. There are pros and cons for each seed category that I assess in the next section. Time shifts are usually increments of TR, e.g. the lag range might be over +/- 5 TRs for a common TR of 2 sec. And, in producing the final lag maps, some studies apply acceptance criteria to reject low correlations.

Let's look at an example time shift analysis, from Siegel et al. (2016). The raw data were filtered with a pass-band of 0.009 - 0.09 Hz. For cross correlations, they used as their seed time course the global gray matter (GM) signal. Cross correlations were computed voxel-by-voxel for nine delays of TR = 2 sec increments, covering +/- 8 sec, followed by interpolation over the lag range. The time shift corresponding to the maximum cross correlation was assigned that voxel's lag value in the final map, as shown here:

Fig. 1 from Siegel et al. (2016).

Friday, January 2, 2015

Potential of ultralow field T1 and high field T1ρ in evaluating brain trauma


Crazy Scientist sent me a link to a paper, "Neuroimaging after mild traumatic brain injury: Review and meta-analysis," (doi:10.1016/j.nicl.2013.12.009) and it prompted me to do something with a brief review I wrote this time last year as a way to plan some research activities on MRI of mild traumatic brain injury (mTBI). By a remarkable coincidence the review paper was made available online four whole days before I completed my own review. I've yet to read the published review so I can't yet tell if I wasted my time. In any event, the document I wrote was for internal consumption (for my collaborators, and to clarify my own thoughts) and was never designed to become a public document. But since our research direction changed mid-year I figured I might as well stick my review out there in case anyone can make use of it.

The title of my document is the same as the title of this post. You will find the contents pasted below, or if you prefer you can download a PDF from this Dropbox link. I have quickly re-read it to check for major bloopers, and I've added a couple of update notes highlighted in yellow. There may well be some direct copy-paste of parts of a few of the papers I reviewed, especially those with heavy neuroradiology content where I am generally a long way out of my depth and would prefer to accept charges of plagiarism than get the medical terminology wrong!

For the record, we are still interested in mTBI but the logistics of studying acute brain injury in a non-hospital setting, using a home-made machine (the ULFMRI) sitting in a second basement lab in a physics department, made it all too hard to pursue right now. We have shifted instead to studying chronic conditions where we have a fighting chance of getting a few people scanned in our unorthodox facilities.